42772
Comment:
|
47354
|
Deletions are marked like this. | Additions are marked like this. |
Line 2: | Line 2: |
There are 2 options in this tutorial, one is to process the entire data set at full resolution, achieving subnanometer resolution. The other makes use of a subset of downsampled data. This will only achieve ~12 Å resolution, but it can be performed on a computer with 16 GB of ram and 4 cores in a reasonable time. The full resolution tutorial should have a well-equipped tomography workstation with at least 64 GB of RAM and preferably at least 16 cores. | '''''Important note: Throughout the tutorial you will see a split between (small) and (large) instructions. The (small) tutorial is designed for laptops or basic desktops and can achieve ~12 Å resolution in a time compatible with live tutorial sessions. The (large) tutorial really requires a proper tomography workstation, but can achieve subnanometer resolution. Do not intermix (small) and (large) options below!''''' |
Line 7: | Line 7: |
* Note that this process starts with raw tilt series. It will not work with tomograms reconstructed and/or CTF corrected in other software. While it is possible to do the first stage of EMAN2 subtomogram averaging with reconstructed tomograms from other software if you use the older pipeline (alignment of 3-D particles). You will never be able to do subtilt refinement or achieve high resolution results. The resolution will remain limited to the resolution provided by the original tomogram. Note, however, that the EMAN2 tilt series alignment/reconstruction is very fast, so we strongly encourage you to try following the EMAN2 pipeline from the beginning. It is far less time consuming than you may think. |
|
Line 11: | Line 13: |
* This reduced version of the tutorial can be completed on a well equipped laptop or standard desktop workstation. | |
Line 15: | Line 16: |
* 40 gb free disk space | * ~40 gb free disk space (small), ~100 gb free disk space, due to larger raw data (large) |
Line 21: | Line 22: |
* (Large) Download only the 4 '''mixed CTEM''' tilt series from EMPIAR: [[https://www.ebi.ac.uk/pdbe/emdb/empiar/entry/10064|EMPIAR 10064]] * (Small) Download the downsampled data from the [[http://eman2.org/Tutorials|EMAN2 Tutorials page]] |
The tutorial data comes from EMPIAR 10064, but only uses a subset of the data from the ''mixed CTEM'' tilt series. * (Large) The 4 fully sampled tilt series [[http://blake.bcm.edu/dl/tutorial_tomo_large.zip]] * (Small) 3/4 tilt series, downsampled by 2x for speed [[http://blake.bcm.edu/dl/tutorial_tomo_small.zip]] |
Line 34: | Line 36: |
* For this project use 3000 kDa, 2.7 mm Cs, 300 keV and 3.93 A/pix. | * For this project use 300 kDa, 2.7 mm Cs, 300 keV and 3.93 (Small) or 1.97 (Large) A/pix. |
Line 41: | Line 43: |
* ''Files'' -> select the 3 provided .hdf files | * ''Files'' -> select the 3 (Small) or 4 (Large) provided .hdf files |
Line 44: | Line 46: |
* ''apix'' = 3.93, in later steps you can use -1, which tells it to use the known value | * ''apix'' = 3.93 (Small) or 1.97 (Large), in later steps you can use -1, which tells it to use the known value |
Line 56: | Line 58: |
== Tiltseries Alignment and Tomogram Reconstruction (10 min) == | == Tiltseries Alignment and Tomogram Reconstruction (~10 min Small) == |
Line 65: | Line 67: |
* ''tltax'' = -4.0 | |
Line 66: | Line 69: |
* ''clipz'' = 64 | * ''clipz'' = 96 |
Line 70: | Line 73: |
* patchtrack = 2 (not really necessary for the tutorial, but shouldn't hurt. This is 3-D patchtracking, not the typical 2-D patchtracking) * extrapad = selected (this will make the tomogram reconstructions take a little longer, but look a bit nicer visually. No impact on the final subtomogram averages) |
|
Line 72: | Line 77: |
If you opted to run with ''notmp'' on one or more tilt series: | If you opted to run without ''notmp'' on one or more tilt series: |
Line 93: | Line 98: |
== Handedness Check (can be skipped in the tutorial) == EMAN2 will automatically locate the tilt axis in a tilt series if it is not provided. Unfortunately there is a +- ambiguity in this determination. An incorrect choice will lead to structures with the incorrect handedness, and may produce suboptimal CTF correction. |
== Handedness Check == EMAN2 will automatically locate the tilt axis in a tilt series if it is not provided, but there is a 180° ambiguity in this determination. An incorrect choice will lead to structures with the incorrect handedness, and may produce suboptimal CTF correction. In some data sets (not the tutorial) this may lead to particles with mixed handedness. Since we specified ''tltax'' above, this step isn't necessary for the tutorial, but you can run it to see what the results look like. |
Line 104: | Line 109: |
* ''dfrange'' = 1.0,4.0,0.02 | |
Line 115: | Line 121: |
If you run this check on multiple images and it seems that they indicate a consistent tilt axis/handedness error, then you need to return to the previous step (Tomogram Reconstruction) and redo the reconstruction for all tomograms, with the correct tilt axis entered in the corresponding box. The same tilt axis should be used for all tilt series collected under the same conditions on the same instrument. ''Note: This method removes __almost__ all of the ambiguity about particle handedness. The one potential issue is that the MRC file format uses a non-conventional origin for images. If the data collection software doesn't take this into account, the images may be flipped when written to disk. The easiest way to check the software would be to collect 2 images of the same target and save them directly into different file formats, then checking (in different software) whether the two images appear to have the same handedness'' |
If you run this check on multiple images and it seems that they consistently indicate a flipped tilt axis/handedness, then you need to return to the previous step (Tomogram Reconstruction) and redo the reconstruction for all tomograms, with the correct tilt axis entered in the corresponding box. The same tilt axis should be used for all tilt series collected under the same conditions on the same instrument. The automatic value may vary a little among micrographs, just compute the approximate average or median value. ''Note: This method removes __almost__ all of the ambiguity about particle handedness. The one potential issue is that the MRC file format uses a non-conventional origin for images. If the data collection software doesn't take this into account, the images may be flipped when written to disk. The easiest way to check the software would be to collect 2 images of the same target and save them directly into different file formats, then checking (in EMAN2) whether the two images appear to have the same handedness''. If not, it is likely that the MRC files are incorrect. |
Line 128: | Line 134: |
* ''checkhand'' = not selected | * ''dfrange'' = 1.0,4.0,0.02 * ''' ''checkhand'' = not selected ''' |
Line 133: | Line 140: |
* The first two options, ''dfrange'' and ''psrange'' indicate the defocus and phase shift range to search. They take the format of “start, end, step”, so “2, 5, .1” will search defocus from 2 to 5 um with a step size of 0.1. Units for phase shift is degrees. | * The first two options, ''dfrange'' and ''psrange'' indicate the defocus and phase shift range to search. It is critical that the actual defocus be within the search range (obviously). They take the format of “start, end, step”, so “2, 5, .1” will search defocus from 2 to 5 um with a step size of 0.1. Units for phase shift is degrees. |
Line 138: | Line 145: |
''Note: In >2022 snapshots of EMAN2 it is possible after CTF correction to return to the 3-D reconstruction step and produce CTF corrected whole tomograms, but this does nothing useful when following the EMAN2 pipeline. If you wish to compare EMAN2 tomograms with other software doing CTF correction, this could potentially be useful'' == Tomogram reconstruction evaluation (optional) == |
''Note: In >=2022 snapshots of EMAN2 it is possible after CTF correction to return to the 3-D reconstruction step and produce CTF corrected whole tomograms, but this does nothing useful when following the EMAN2 pipeline. If you wish to compare EMAN2 tomograms with other software doing CTF correction, this could potentially be useful'' == Tomogram reconstruction evaluation == |
Line 145: | Line 152: |
The ''correctrot'' option often does not work well on tutorial tomo3. If you go through the tomograms you should see ribosomes spanning the plane of the image for all of the tomograms. If tomo3 shows only a narrow band containing ribosomes, return to the tomogram reconstruction step above, and re-run the process for only that tomogram (uncheck ''alltiltseries'', and select tiltseries/*tomo3.hdf. Also uncheck ''correctrot''). |
|
Line 146: | Line 155: |
* Selecting a tomogram will show a thumbnail in the image pane on the right. | |
Line 173: | Line 183: |
1. A new deep-learning based 3-D picker. Not available in 2.91, must use a recent (2022+) snapshot. | |
Line 176: | Line 187: |
1. A new deep-learning based 3-D picker. Not available in 2.91, must use a recent snapshot. See: [[EMAN2/e2tomo_more#Automated_particle_selection|New automatic particle picking]] For live versions of this tutorial, we use the older manual+template based approach as it requires no specific hardware, and is a good learning experience, but the deep learning 3-D picker is a good choice for many situations. For cellular tomograms, the annotation tool approach may still be a good choice. === (1) Tomogram annotation (GPU recommended) === |
For live versions of this tutorial, we use the older manual+template based approach as it requires no specific hardware, and is a good learning experience, but the deep learning 3-D picker is a good choice for typical situations. For cellular tomograms, the annotation tool approach may still be a good choice. === New Deep-Learning 3-D Picker (recommended approach) === This is the easiest approach by far, and is basically a single step process, but is only available in recent (2022+) snapshots of EMAN2. * You should easily be able to select ~500 particles per tomogram, potentially more, but 500 is more than sufficient for the tutorial * For instructions, see: [[EMAN2/e2tomo_more#Automated_particle_selection|New automatic particle picking]] * When complete, skip ahead to the next major section '''Particle Extraction''' === Tomogram annotation (GPU recommended) === |
Line 206: | Line 222: |
== Manual particle picking (10-15 min) == | === Manual particle picking (10-15 min) === |
Line 232: | Line 248: |
== Particle extraction (2 min) == In this pipeline, the full 1k or 2k tomograms are used only as a reference to identify the location of the objects to be averaged. Now that we have particle locations, the software returns to the original tilt-series, extracts a per-particle tilt-series, and reconstructs each particle in 3-D independently. |
== Particle extraction (~2 min (a few manual) - hours (a couple of thousand)) == Note that this step will be vastly different resource-wise if you are only extracting a few manually selected particles for purposes of later template matching or if you already selected hundreds of particles from each tomogram. The reduced 1k x 1k (or 2k) tomograms are used only as a reference to identify the location of the objects to be averaged. Now that we have particle locations, the software returns to the original tilt-series, extracts a per-particle tilt-series, and reconstructs each particle in 3-D independently at full resolution. Since this is performing a full resolution reconstruction of each particle it is somewhat resource intensive. |
Line 239: | Line 257: |
* set ''boxsz_unbin'' to 128. | * set ''boxsz_unbin'' to 128 (Small) or 256 (Large). |
Line 241: | Line 259: |
* It is fine to use a different (usually larger) box size here if you find it easier to select particles with a smaller box size. For the tutorial, stick with 128, though. * enter the label you used when picking particles ("initribo" if you followed the instructions above) |
* enter the label you used when picking particles ("initribo" if you manually boxed, "tomobox" if you used the deep learning picker) |
Line 259: | Line 276: |
While intuitively it seems like (since the particles are already in 3-D) the concept of an "initial model" should not be necessary. Unfortunately, due to the missing wedge, and the low resolution of one individual particle (particularly from cells), it is actually critical to make a good starting average. Historically it has been challenging to get a good starting model, depending on the shape of the molecule. This new procedure based on stochastic gradient descent has proven to be quite robust, but it is difficult for the computer to tell when it has converged sufficiently. For this reason, the default behavior is to run much longer than is normally required, and have a human decide when it's "good enough" and terminate the process. If you use a small ''shrink'' value and let it run to completion, it can take some time to run. This is harmless, but unnecessary. While the section below the solid line remains fully functional, a new program available since 2021 does a much more efficient job of making initial models. It hasn't been integrated into e2projectmanager yet, but it is enough of an improvement, we will go ahead and use it here regardless. The original instructions are preserved below the horizontal line if you prefer the older approach. | While intuitively it seems like (since the particles are already in 3-D) the concept of an "initial model" should not be necessary. Unfortunately, due to the missing wedge, and the low resolution of one individual particle (particularly from cells), it is actually critical to make a good starting average. Historically it has been challenging to get a good starting model, depending on the shape of the molecule. This new procedure based on stochastic gradient descent has proven to be quite robust, but it is difficult for the computer to tell when it has converged sufficiently. For this reason, the default behavior is to run much longer than is normally required, and have a human decide when it's "good enough" and terminate the process. If you use a small ''shrink'' value and let it run to completion, it can take some time to run. This is harmless, but unnecessary. While the section below the solid line remains fully functional, a new program available since 2021 does a much more efficient job of making initial models. |
Line 264: | Line 281: |
The new initial model generator was only added to e2projectmanager in Feb 2022, so if you have an older version, you may need to run it from the command-line. If it isn't available from the command-line either, you will need to use the older tool below. | The new initial model generator was only added to e2projectmanager in Feb 2022, so if you have an older version, you may need to run it from the command-line. If it isn't available from the command-line either, you should probably update. |
Line 269: | Line 286: |
* ''niter'' = 10 You may make this up to 100, and simply kill the job when the model seems good enough. 10 is fine for this tutorial, and often you can even stop after ~5 * ''shrink'' = 2 For speed during live tutorials |
* ''niter'' = 10 You may make this up to 100, and simply kill the job when the model seems good enough. 10 is fine for this tutorial, and often you can even stop after 3-5 * ''shrink'' = 2 (Small) or 4 (Large) |
Line 301: | Line 318: |
This section is the older program, which is still functional, and is integrated into the project manager | This section is the older program, which is still functional, but not recommended. Skip this if you already used the new version above. |
Line 322: | Line 339: |
== Template matching (5 min) == In this step, we will use the initial model you just produced as a template for finding all of the ribosomes in all 3 tomograms. If you completed the '''Tomogram Annotation''' step above, and have already extracted a full set of 1000+ particles, then you can skip this step, as we already have all of the particles. Note that here, and everywhere else in the tomography pipeline, reconstructed particles have positive contrast (look white in projection) and tomograms/tilt series have negative contrast (look dark in projection). If you wish to use a reference volume from the PDB or somesuch, then it should have positive contrast as is normal in the single particle CryoEM field. |
== Template matching (ONLY if you manually boxed above) == If you manually boxed only a few particles in the steps above rather than using one of the semi-automated methods to pick the full 1000 - 3000 particles, then you will now need to use template matching to box out all of the particles. If you already have a set of 1000-3000 particles, skip ahead to '''New Integrated Refinement Program''' Note that here, and everywhere else in the tomography pipeline, reconstructed particles have positive contrast (look white in projection) and tomograms/tilt series have negative contrast (look dark in projection). If you wish to use a reference volume from the PDB or somesuch, then it should have positive contrast as is normal in the single particle CryoEM field. |
Line 345: | Line 364: |
== Particle extraction (~15 min) == | === Particle extraction (ONLY if not done for full data above) === |
Line 354: | Line 373: |
* ''boxsz_unbin'' = 128 | * ''boxsz_unbin'' = 128 (Small) or 256 (Large) |
Line 359: | Line 378: |
== Build Sets (again) == | === Build Sets (again) === It's harmless to repeat this, as it's almost instantaneous, and overwrites existing files. |
Line 368: | Line 389: |
There is a new refinement program which implements both traditional subtomogram averaging and subtilt refinement in a single program. This is an alternative to the next two major sections (Subtomogram Refinement and Subtilt Refinement). The full tutorial on the new program is [[https://blake.bcm.edu/emanwiki/EMAN2/e2tomo_new|here]]. Integration of this program into e2projectmanager isn't quite complete yet (but should be by mid-March 2022). For the moment, we will run this command directly from the command-line. We will do this as 2 sequential refinement runs for efficiency, and to show how you can continue a refinement. The initial refinement should turn the initial model into something ribosome shaped, but at low resolution. The second refinement should get to ~12 Å resolution. |
There is a new refinement program which implements both traditional subtomogram averaging and subtilt refinement in a single program. This is an alternative to the next two major sections (Subtomogram Refinement and Subtilt Refinement). The full tutorial on the new program is [[https://blake.bcm.edu/emanwiki/EMAN2/e2tomo_new|here]]. It was integrated into e2projectmanager in mid-2022, so make sure you have an up to date version. === Small (large below) === In the small tutorial will do this as 2 sequential refinement runs for efficiency, and to show how you can continue a refinement. The initial refinement should turn the initial model into something ribosome shaped, but at low resolution. The second refinement should get to ~12 Å resolution. |
Line 399: | Line 419: |
That's it. You hopefully have a ~12 Å resolution map. If you wish to try and push the resolution further, you can download the original 4k tilt series from EMPIAR and pick all of the particles (instead of just ~450), and go through the process again. | That's it. You hopefully have a ~12 Å resolution map. If you wish to try and push the resolution further, you can follow the Large version of the tutorial |
Line 403: | Line 423: |
=== Large === The Large data set should have 1000-3000 particles at full sampling, and should readily achieve ~6.5 Å resolution. This is really designed to run on a workstation, not a laptop. * In mid-2022+ versions, this is available from the project manager as '''New 3D Refinement''', you can enter the options from the command below if you prefer to run it that way. * You may need to replace ''sets/tomobox.lst'' with whatever you named your set. * --ref should point at whatever initial model you want to use * Replace both ''4''s with the number of threads for your machine. * Replace /home/username/tmp with a folder on a local hard-drive with a decent amount of free space (several GB at a minimum) {{{ e2spt_refine_new.py --ptcls=sets/tomobox.lst --ref=sptsgd_00/output_cls0.hdf --startres=50.0 --goldstandard --sym=c1 --iters=p,p,p,t,t,t --keep=0.95 --tophat=global --parallel=thread:4:/home/username/tmp --threads=4 --m3dthread }}} If you like you could use the modified iters sequence: p,p,p,t,t,r,d,t but this will take considerably longer to run, and likely produce only very slightly improved results. This alternative includes in-plane rotational subtilt refinement and defocus refinement. You can (and probably should) look at the results while the job is runing, you should have a ''spt_00'' folder containing the results each completed iteration. You may take a look at: * fsc_maskedtight_XX.txt - These are the masked gold-standard resolution curves after each iteration. Double click in the EMAN2 browser to plot them. * threed_XX.hdf - These are the 3D maps after each iteration. Again, double-click in the browser to visualize. That's it. You hopefully have a ~6.5 Å resolution map when the job finishes, and it should get pretty close to that after 4-6 iterations. Skip the next 2 sections about the old refinement. Other notes are below that. |
EMAN2 Tomography and Subtomogram/Subtilt Averaging Workflow Tutorial
Important note: Throughout the tutorial you will see a split between (small) and (large) instructions. The (small) tutorial is designed for laptops or basic desktops and can achieve ~12 Å resolution in a time compatible with live tutorial sessions. The (large) tutorial really requires a proper tomography workstation, but can achieve subnanometer resolution. Do not intermix (small) and (large) options below!
- This tutorial requires EMAN 2.91 at a minimum. The newer pipeline, which will become the primary pipeline in EMAN3, is also discussed. To use those instructions you should have a current EMAN2.99 snapshot version.
Some additional documentation for the newer pipeline for integrated subtomogram and subtilt refinement can be found in TomoNew
Documentation of some other recently developed tools can be found in TomoMore.
- Note that this process starts with raw tilt series. It will not work with tomograms reconstructed and/or CTF corrected in other software. While it is possible to do the first stage of EMAN2 subtomogram averaging with reconstructed tomograms from other software if you use the older pipeline (alignment of 3-D particles). You will never be able to do subtilt refinement or achieve high resolution results. The resolution will remain limited to the resolution provided by the original tomogram. Note, however, that the EMAN2 tilt series alignment/reconstruction is very fast, so we strongly encourage you to try following the EMAN2 pipeline from the beginning. It is far less time consuming than you may think.
- To cite:
- Chen, M., Bell, J.M., Shi, X. et al. A complete data processing workflow for cryo-ET and subtomogram averaging. Nat Methods 16, 1161–1168 (2019)
Computer Requirements
- Minimum recommended configuration:
- 16 GB RAM (small), 64 GB RAM (large)
4 cores @ >2 ghz (small), 16 cores (large)
- ~40 gb free disk space (small), ~100 gb free disk space, due to larger raw data (large)
- a high performance disk (SSD or RAID) will significantly reduce runtimes
Note: Any place in EMAN2 where you are requested to enter the number of threads to use, you should specify the number of cores your machine has. Computers are often advertised as 4 core/8 thread or 8 core/16 thread. Trying to run image processing using this advertised number of threads will usually make processing run slower, not faster. You may optionally increase the number of cores by ~25%, ie - on a 4 core machine, specifying 5 may give a 5-10% speedup over 4
Download Data
The tutorial data comes from EMPIAR 10064, but only uses a subset of the data from the mixed CTEM tilt series.
(Large) The 4 fully sampled tilt series http://blake.bcm.edu/dl/tutorial_tomo_large.zip
(Small) 3/4 tilt series, downsampled by 2x for speed http://blake.bcm.edu/dl/tutorial_tomo_small.zip
Prepare input files (~2 minutes)
- Make a new empty folder for the project and 'cd' into that folder
run e2projectmanager.py:
e2projectmanager.py&
- Make sure any EMAN2 commands you run are executed from within this folder (not any subfolder)
- You may use "Edit Project" from the Project menu to set default values for the project.
If you downloaded our prepared data set, it will already contain an info folder containing the project settings, so you should not need to change anything.
- For this project use 300 kDa, 2.7 mm Cs, 300 keV and 3.93 (Small) or 1.97 (Large) A/pix.
- The mass need not be precise, it is only used to keep isosurface values roughly self-consistent.
- Make sure the workflow mode is set to "TOMO" not "SPR"
Raw Data -> Import tilt series
Files -> select the 3 (Small) or 4 (Large) provided .hdf files
rawtlt, mdoc -> leave these blank
invert should not be selected
apix = 3.93 (Small) or 1.97 (Large), in later steps you can use -1, which tells it to use the known value
import_tiltseries = selected
importation = copy
compressbits = 5 (8 is fine as well, but will make file sizes slightly larger)
Once the options are set, press Launch
When working with your own data:
- It is critical that the filenames for your data not contain any spaces (replace with underscore) or periods (other than the final period used for the file extension).
"__" (double underscore) is also reserved for describing modified versions of the same file, and should not be used in your image filenames.
If your tilt series isn't a single stack file, but is many individual images instead, you will need to use Generate tiltseries to build an image stack
Tiltseries Alignment and Tomogram Reconstruction (~10 min Small)
Alignment of the tilt-series is performed iteratively in conjunction with tomogram reconstruction. Tomograms are not normally reconstructed at full resolution, generally limited to 1k x 1k or 2k x 2k, but the tilt-series are aligned at full resolution. For high resolution subtomogram averaging, the raw tilt-series data is used, based on coordinates from particle picking in the downsampled tomograms. On a typical workstation reconstruction takes about 4-5 minutes per tomogram.
For the tutorial tilt-series:
3D Reconstruction -> Reconstruct Tomograms
alltiltseries = selected
alternatively you can select one or more tilt series from the tiltseries folder
correctrot = selected
tltax = -4.0
tltstep = 2
clipz = 96
threads = number of physical cores on your machine, optionally *1.25.
notmp = checked by default. If you wish to look at the intermediate aligned tilt-series and other files, uncheck this, but note that this will significantly increase disk requirements
- These files are not required for the remaining steps in the tutorial, but can be used to help understand how the tomogram alignment works. You may consider doing this for only one tomogram.
- patchtrack = 2 (not really necessary for the tutorial, but shouldn't hurt. This is 3-D patchtracking, not the typical 2-D patchtracking)
- extrapad = selected (this will make the tomogram reconstructions take a little longer, but look a bit nicer visually. No impact on the final subtomogram averages)
- Launch
If you opted to run without notmp on one or more tilt series:
You will see a tomorecon_XX folder for each tilt series, containing:
landmark_0X.txt has the location of the landmarks (which may be fiducials if present) in each iteration
samples_0X.hdf shows the top and side view of those landmarks
ptclali_0X.hdf has the trace of each landmark throughout the tilt series (they should stay at the center of image all the time if the alignment is good)
tomo_0X.hdf is the reconstruction after each iteration
Again, note that these files are not required by any downstream processing. If you have difficulty getting a particular tilt series to reconstruct, and the patchtrack=2 option doesn't help, this may help debug the problem. However, if you do encounter problems, we would like to invite you to ask about it either publicly on the mailing list or privately to the developers.
When working with your own data:
We strongly recommend reconstructing at most 5-10 tilt series to start. Then completing the handedness check in the next step before returning to this step and reconstructing the full set of tilt series! This will allow you to specify the correct tltax value.
Either specify the correct tltstep if the tilt series is in order from one extreme to the other, or specify the name of a rawtlt file (as produced by serialem/IMOD).
In most cases, the default npk should be fine. If fiducials are present, it is not necessary to adjust this number to match the number of fiducials. The program will use any high contrast areas it finds as potential landmarks.
bytile should normally be selected, as it will normally produce better quality reconstructions at higher speed. If 2k or larger tomograms are created, memory consumption may be high, and you should check the program output for the anticipated RAM usage.
- The graphical interface only permits 1k or 2k reconstruction sizes. In our experience this is normally sufficient for segmentation or particle picking.
When the sample is thick, some grid-like tiling pattern can be seen in the reconstruction. Checking extrapad can largely reduce the artifacts. In versions after 2/3/2020, there is also a moretile option that further eliminates them. Note these artifacts will NOT impact the subtomogram averaging results because the particles are extracted in a separate process. Checking these options can make the reconstruction process more memory consuming, and up to 5 times slower.
When the sample is thin (purified protein, not cells), it is useful to check correctrot to automatically position tomograms flat in ice
It can also be helpful with thin ice to specify a clipz value to generate thinner tomograms (perhaps 64 or 96 for a 1k tomogram).
There is a new patchtrack option which may help with refinements that otherwise don't seem to be aligning well. Note that this is not conventional 2-D patchtracking, but a novel 3-D patchtracking routine. This acts as a preprocessing step if specified (2 is recommended).
Handedness Check
EMAN2 will automatically locate the tilt axis in a tilt series if it is not provided, but there is a 180° ambiguity in this determination. An incorrect choice will lead to structures with the incorrect handedness, and may produce suboptimal CTF correction. In some data sets (not the tutorial) this may lead to particles with mixed handedness. Since we specified tltax above, this step isn't necessary for the tutorial, but you can run it to see what the results look like.
EMAN2 includes a novel procedure for resolving this ambiguity from a tilt series based on defocus estimates across the tilted images. The tutorial data set comes out correctly without running this check, but when working with your own data, this step is highly recommended. Once you know the correct tilt axis direction to use for a given microscope/camera, you shouldn't need to run this test on every data set, but it may not be a bad idea even then, as there are various possible configuration/software errors on the instrument which could potentially cause inconsistent results, particularly with a change of magnification.
For the tutorial tilt-series:
Subtomogram Averaging -> CTF Estimation
tiltseries = select any one tilt series
alltiltseries = not selected
voltage and cs (double check that values are correct)
dfrange = 1.0,4.0,0.02
checkhand = selected
- Launch
You will need to look at the console where you launched e2projectmanager to see the results of the test. It should look something like:
Average score: Current hand - 4.133, flipped hand - 3.290 Defocus std: Current hand - 0.110, flipped hand - 0.165 Current hand is better than the flipped hand in 86.4% tilt images The handedness (--tltax=-4.1) seems to be correct. Rerun CTF estimation without the checkhand option to finish the process.
If you run this check on multiple images and it seems that they consistently indicate a flipped tilt axis/handedness, then you need to return to the previous step (Tomogram Reconstruction) and redo the reconstruction for all tomograms, with the correct tilt axis entered in the corresponding box. The same tilt axis should be used for all tilt series collected under the same conditions on the same instrument. The automatic value may vary a little among micrographs, just compute the approximate average or median value.
Note: This method removes almost all of the ambiguity about particle handedness. The one potential issue is that the MRC file format uses a non-conventional origin for images. If the data collection software doesn't take this into account, the images may be flipped when written to disk. The easiest way to check the software would be to collect 2 images of the same target and save them directly into different file formats, then checking (in EMAN2) whether the two images appear to have the same handedness. If not, it is likely that the MRC files are incorrect.
CTF Estimation (<5 min)
Do NOT forget this step!
This step will determine the defocus as a function of location for each tilt in each tilt series. This information is stored in the headers of particles as they are extracted from the tilt series, and used for CTF correction during subtomogram averaging. If you forget to do this, you will need to re-run the particle extraction step, which is quite time consuming.
For the tutorial tilt-series:
Subtomogram Averaging -> CTF Estimation
alltiltseries = selected, note that doing this will override anything present in the tiltseries field
dfrange = 1.0,4.0,0.02
checkhand = not selected
- Launch
When working with your own data:
The first two options, dfrange and psrange indicate the defocus and phase shift range to search. It is critical that the actual defocus be within the search range (obviously). They take the format of “start, end, step”, so “2, 5, .1” will search defocus from 2 to 5 um with a step size of 0.1. Units for phase shift is degrees.
For images taken with volta phase plate, we usually have dfrange of “0.2,2,0.1” and psrange of “60,120,2”.
Note: this program is only estimating CTF parameters, taking tilt into account. It is not performing any phase-flipping corrections on whole tomograms. CTF correction is performed later as a per-particle process. This process requires metadata determined during tilt-series alignment, so it cannot be used with tomograms reconstructed using other software packages.
Note: In >=2022 snapshots of EMAN2 it is possible after CTF correction to return to the 3-D reconstruction step and produce CTF corrected whole tomograms, but this does nothing useful when following the EMAN2 pipeline. If you wish to compare EMAN2 tomograms with other software doing CTF correction, this could potentially be useful
Tomogram reconstruction evaluation
Analysis and visualization -> Evaluate tomograms can be used to evaluate the quality of your tilt series alignments and tomogram reconstructions. This tool will show more information as you progress through the tutorial, but can be used already at this point to make various assessments of your tomograms. Note that some of this information may not be available if you had notmp checked during the reconstruction.
The correctrot option often does not work well on tutorial tomo3. If you go through the tomograms you should see ribosomes spanning the plane of the image for all of the tomograms. If tomo3 shows only a narrow band containing ribosomes, return to the tomogram reconstruction step above, and re-run the process for only that tomogram (uncheck alltiltseries, and select tiltseries/*tomo3.hdf. Also uncheck correctrot).
- On the left is a list of tomograms in the project.
- Selecting a tomogram will show a thumbnail in the image pane on the right.
- Clicking the header of any column will sort the table by that attribute.
#box is the number of boxes in the tomogram
loss is the average landmark uncertainty in nm. You should not try to compare this number to, for example, the fiducial alignment error in IMOD, as it is computed in a completely different way. This number can be useful to identify specific tilt series within a project which aren't aligning as well as others, but the absolute number is not a useful value to report/analyze. Even if this number were >5 nm, it is still quite possible to achieve a subnanometer resolution subtomogram average.
defocus is the average defocus of the tilt series.
- On the right
- The image at the top is the central slice through the tomogram
the show2d button displays the selected tomogram in a slice-wise view.
ShowTilts shows the corresponding raw tilt series
- Please note that most tomograms include some out-of-plane tilt (the actual rotation isn't a simple tilt along a single axis), which is taken into account during alignment. This may make it visually appear that the tilt series alignment is not as robust as it actually is.
Boxer opens the 3D particle picker
PlotLoss will plot the fiducial error for each tilt
PlotCtf plot the defocus and phase shift at the center of each tilt image
Tiltparams is a bit more complicated. It plots a point list with 6 columns and a number of rows corresponding to the images in the selected tilt series. These are the alignment parameters for the tilt series.
You can adjust X Col and Y Col in the plot control panel (middle click the plot). The columns represent:
- 0 - tilt ID
- 1 - translation along x
- 2 - translation along y
- 3 - tilt angle around y
- 4 - tilt angle around x
- 5 - tilt angle around z
- The first panel below the buttons are the types of particles and how many of that type are in the project
- The last box is reserved for comments for each tomogram. You can fill in any comments you have on a specific tomogram and it will be saved for future reference.
Particle Picking Choices
There are 4 different tools you can use for particle picking in EMAN2 as of Feb 2022:
- A new deep-learning based 3-D picker. Not available in 2.91, must use a recent (2022+) snapshot.
- Abusing the deep-learning based segmentation tool for particle picking purposes
- Manual particle picking
- Template based picking (usually seeded with some manual picking results)
For live versions of this tutorial, we use the older manual+template based approach as it requires no specific hardware, and is a good learning experience, but the deep learning 3-D picker is a good choice for typical situations. For cellular tomograms, the annotation tool approach may still be a good choice.
New Deep-Learning 3-D Picker (recommended approach)
This is the easiest approach by far, and is basically a single step process, but is only available in recent (2022+) snapshots of EMAN2.
- You should easily be able to select ~500 particles per tomogram, potentially more, but 500 is more than sufficient for the tutorial
For instructions, see: New automatic particle picking
When complete, skip ahead to the next major section Particle Extraction
Tomogram annotation (GPU recommended)
- Since the tutorial data set is purified ribosomes, this step can be skipped for the tutorial data, and you can move on to template-based particle picking. For cells or other types of complex specimens, tomogram annotation can be used to more easily distinguish locations of different types of objects.
For a detailed description of how to use the annotation tool, see: TomoSeg
Here is a brief summary of the annotation-based approach:
Segmentation -> Preprocess tomogram
- This step is not always necessary for tomograms reconstructed in EMAN2, but may slightly improve results.
Segmentation -> Box Training References
- This is a newer interface than previously used for this step. Select a few "Good" (regions containing the feature of interest) and "Bad" (regions not containing the feature of interest) boxes.
- "~" and "1" on the keyboard can be used to move along the Z axis.
- The new interface permits different types of features to be identified in a single session and in the same tomogram.
If the different features of interest have very different scale, it is always better to keep the box size at 64, and instead rescale the tomogram. As long as the rescaling is done using EMAN2 utilities, the program will correctly keep track of the geometry relative to the original tomogram & tilt series.
- if you are doing this with the tutorial data, you would only have 2 classes of particles "ribo_good" and "ribo_bad".
When pressing Save all visible particles (box checked next to the class name) will be saved
The rest of the annotation process remain unchanged from the original tutorial, except that now, all trained neural networks and training results are saved in the neuralnets folder, and all segmented maps are in the segmentations folder. You now only specify the label of the output file instead of the full file name.
Segmentation -> Find particles from segmentation to turn segmented maps into particle coordinates.
- Input both the tomogram and its corresponding segmentation, and the particles coordinates will be written into the metadata file.
- Slightly tweaking the threshold parameters may yield better results.
featurename will become the label of particles generated. Those particles can be viewed in the particle picking step and processed in the following protocols.
Manual particle picking (10-15 min)
- Time above is to manually select 30-50 reference particles.
- You can launch the particle picker in two equivalent ways:
Subtomogram averaging -> Manual boxing, select tomogram, Launch
Analysis and visualization -> Evaluate tomograms as above, press the "Boxer" button
two windows will appear Main Window and Options. If you don't see Options it is probably hiding behind the main window.
in the Options window, rename the set of boxes to "initribo". This will be used as the label in later stages
- The box size can be set in the main window at the left bottom corner, for this tutorial, use 32 for ribosomes (the unbinned box size is 128).
This is NOT the same as the size listed near the word erase in another window, which is the size of the eraser.
- left click and drag to place and reposition boxes in any of the 3 views
- Hold down Shift when clicking to delete existing boxes.
- Boxes are shown as circles, which vary in size depending on the Z distance from the center of the particle.
- If you accidentally include one or more particles with nearby gold fiducials or other high contrast artifacts, it may cause some issues with your generated model (do not do that).
Go through slices along z-axis using ‘~’ and ‘1’ on the keyboard, or using the slider in the lower right of the window
It may be easier to locate particles if you adjust the Filt slider to ~70, but it will slow things down
- The interface supports different box types within a single tomogram. Each type has a label. Make sure the label is consistent if selecting the same feature in different tomograms.
- If you skipped the tomogram annotation step, we will pick a few particles here to generate an initial model, and use the initial model as a reference for template matching.
- Select 30-50 particles from one tomogram, then close the boxer window.
Do not use the Save button in the Options window or any of the menu items related to saving data. Those are available for special purposes. When you change the boxes, your changes are saved immediately and automatically. When you are done, simply close the main window.
- If you did the previous optional annotation step above, you will be able to see the selected particles here, and if you like, manually update them.
Particle extraction (~2 min (a few manual) - hours (a couple of thousand))
Note that this step will be vastly different resource-wise if you are only extracting a few manually selected particles for purposes of later template matching or if you already selected hundreds of particles from each tomogram.
The reduced 1k x 1k (or 2k) tomograms are used only as a reference to identify the location of the objects to be averaged. Now that we have particle locations, the software returns to the original tilt-series, extracts a per-particle tilt-series, and reconstructs each particle in 3-D independently at full resolution. Since this is performing a full resolution reconstruction of each particle it is somewhat resource intensive.
For the tutorial tilt-series:
Subtomogram Averaging -> Extract Particles
check alltomograms
set boxsz_unbin to 128 (Small) or 256 (Large).
- If you had the correct size in the previous step this should be the same as leaving the default -1
- enter the label you used when picking particles ("initribo" if you manually boxed, "tomobox" if you used the deep learning picker)
threads = value for your machine
- Launch
Subtomogram Averaging -> Build Sets
check allparticles
- Launch
- This will generate particle sets, which are virtual particle stacks that consist of particles with the same label from different tomograms.
For your own data
If the box size is correct when you select particles from the GUI, you can leave boxsz_unbin as -1, so the program will keep that box size (scaled to the original tilt series)
If your particles are deeply buried in other densities, using a bigger padtwod may help, but doing so may significantly increase the memory usage and slow down the process.
With CTF information present, it generally does not hurt to check wiener, which filters the 2D particles by SSNR before reconstructing them in 3D.
Specify a binning factor in shrink to produce downsampled particles if your memory/storage/CPU time is limited, but it will also limit the resolution you can achieve.
Initial model generation (10 - 60 min)
While intuitively it seems like (since the particles are already in 3-D) the concept of an "initial model" should not be necessary. Unfortunately, due to the missing wedge, and the low resolution of one individual particle (particularly from cells), it is actually critical to make a good starting average. Historically it has been challenging to get a good starting model, depending on the shape of the molecule. This new procedure based on stochastic gradient descent has proven to be quite robust, but it is difficult for the computer to tell when it has converged sufficiently. For this reason, the default behavior is to run much longer than is normally required, and have a human decide when it's "good enough" and terminate the process. If you use a small shrink value and let it run to completion, it can take some time to run. This is harmless, but unnecessary. While the section below the solid line remains fully functional, a new program available since 2021 does a much more efficient job of making initial models.
New Initial Model Generator
The new initial model generator was only added to e2projectmanager in Feb 2022, so if you have an older version, you may need to run it from the command-line. If it isn't available from the command-line either, you should probably update.
Subtomogram Averaging -> New initial model generator
particles = Browse for sets/initribo.lst (or whatever you called your set)
res = 50 This is a low resolution initial model. No reason to push it.
niter = 10 You may make this up to 100, and simply kill the job when the model seems good enough. 10 is fine for this tutorial, and often you can even stop after 3-5
shrink = 2 (Small) or 4 (Large)
parallel = thread:4 Replace this with the correct number of threads for your machine as above. If you have limited disk space on /tmp, you can also specify a temporary folder: thread:4:/home/username/tmp
Launch
If you do not see New initial model generator in e2projectmanager, you can run it from the command line, replacing appropriate options:
e2spt_sgd_new.py sets/initribo.lst --res 50 --niter 10 --shrink 2 --parallel thread:4
The second program will produce output like:
Gathering metadata... 69/69 iter 0, class 0: 17 jobs on 4 CPUs iter 1, class 0: 17 jobs on 4 CPUs iter 2, class 0: 17 jobs on 4 CPUs
Once it gets past 3-4 iterations, you can use the browser to look in sptsgd_00, and double-click on output_cls0.hdf. This file will change after each iteration completes. It contains the results of the most recent iteration. When you are satisfied with the quality of the initial model, you can kill it with the task manager in e2projectmanager.
For your own data:
If your particle has known symmetry, specify that EMAN2/Symmetry
setting shrink to something in the range of 2-4 will make the runtime faster but, depending on the shape, could potentially cause problems.
- using more than the minimal 30-50 particles is fine. If you have a very large set of selected particles, go ahead and use them all. This will not slow the process down at all, since it's stochastic.
it is critical that the full sampling box size of the extracted particles divided by shrink be divisible by 2. If not, the program will crash.
Old Initial Model Generator
This section is the older program, which is still functional, but not recommended. Skip this if you already used the new version above.
For the tutorial tilt-series:
Subtomogram Averaging -> Generate Initial Model
particles should be set to the sets/initribo.lst file you just created (or whatever name you used).
set shrink to 2, 3 or 4
- 2 will run slowly but will produce a more detailed initial model (not really necessary)
increasing batchsize will use more cores (if you have more than 12), and may cause it to converge to the correct answer in fewer iterations, but each iteration will not become faster.
The default niter of 5 is typically much more than is required
- Launch
You can terminate the job as soon as sptsgd_00/output.hdf looks reasonable. If you display the progress monitor (4th icon on the right side of the project manager), you can easily kill the job when you're happy. Usually this will take about 10 minutes for the tutorial data.
For your own data:
If your particle has known symmetry, specify that EMAN2/Symmetry
The symmetry you specify will not be imposed on the map unless you also check applysym, but the map will be rotationally aligned so the symmetry axes are in the correct direction, which will make it easier to apply symmetry in later steps. We do not generally recommend checking this box in this step.
setting shrink to something in the range of 2-4 will make the runtime faster but, depending on the shape, could potentially cause problems.
- using more than the minimal 30-50 particles is fine. If you have a very large set of selected particles, go ahead and use them all. This will not slow the process down at all, since it's stochastic.
it is critical that the full sampling box size of the extracted particles divided by shrink be divisible by 2. If not, the program will crash.
Template matching (ONLY if you manually boxed above)
If you manually boxed only a few particles in the steps above rather than using one of the semi-automated methods to pick the full 1000 - 3000 particles, then you will now need to use template matching to box out all of the particles. If you already have a set of 1000-3000 particles, skip ahead to New Integrated Refinement Program
Note that here, and everywhere else in the tomography pipeline, reconstructed particles have positive contrast (look white in projection) and tomograms/tilt series have negative contrast (look dark in projection). If you wish to use a reference volume from the PDB or somesuch, then it should have positive contrast as is normal in the single particle CryoEM field.
Subtomogram Averaging -> Reference Based Boxing
tomograms -> browse and select all 3 tomograms.
reference = the initial model you produced in the previous step
label = ribo
nptcl = 150
IMPORTANT NOTE: There are more particles than this in these images. We limit this to 150 from each tomogram so the tutorial runs faster. If you are unconcerned with speed, you can increase this number, but if you're doing that, you may consider running the full tutorial instead.
vthr = 5
- if using an older version of EMAN2, you may wish to use the default of 10, but with the current version, 10 may not find any particles and crash.
- This threshold is in terms of the number of standard deviations above the mean. The definition was slightly different when the default was 10.
threads = the usual number
- Launch
- Note: if you see an error, with some mention of zero, it is likely you forgot to reduce vthr to 5.
when this finishes, you can use the same Manual Boxing tool you used before to look at the particles which were selected. You may wish to manually remove any bad particles it selected. For the tutorial data set or other tomograms of purified protein, this process should work pretty well.
- note that this process stores 3-D particle locations in the appropriate info/* files, but does not extract particles from the micrographs
For your own data:
- Frankly, in most cases the deep learning based picker will do a better job. For cells, you may consider the full Tomogram Annotation tool. This program works with highly downsampled tomograms and references for speed.
Picking a good vthr and a reasonable nptcl maximum may take a little trial and error. Test on 1-3 tomograms before the full run.
Particle extraction (ONLY if not done for full data above)
If you already extracted a complete set of particles (not just the few initial references) above, you don't need to repeat it again here.
Since this involves several hundred particles instead of 30-50, it will take quite a lot longer to run.
For the tutorial tilt-series:
Subtomogram Averaging -> Extract Particles
check alltomograms
boxsz_unbin = 128 (Small) or 256 (Large)
label = ribo
compressbits = 5
- Launch
Build Sets (again)
It's harmless to repeat this, as it's almost instantaneous, and overwrites existing files.
Subtomogram Averaging -> Build Sets
check allparticles
You can leave label blank. It will just regenerate all of the .lst files.
- Launch
- This will generate particle sets, which are virtual particle stacks that consist of particles with the same label from different tomograms.
- Generally just takes a few seconds. If you have a large project with hundreds of tomograms it will take a bit longer.
New integrated refinement program
There is a new refinement program which implements both traditional subtomogram averaging and subtilt refinement in a single program. This is an alternative to the next two major sections (Subtomogram Refinement and Subtilt Refinement). The full tutorial on the new program is here. It was integrated into e2projectmanager in mid-2022, so make sure you have an up to date version.
Small (large below)
In the small tutorial will do this as 2 sequential refinement runs for efficiency, and to show how you can continue a refinement. The initial refinement should turn the initial model into something ribosome shaped, but at low resolution. The second refinement should get to ~12 Å resolution.
You may need to replace sets/ribo.lst with whatever you named your set.
Replace both 4s with the number of threads for your machine.
- If you didn't use the "new" style initial model generation above, you may also need to alter --ref.
e2spt_refine_new.py --ptcls sets/ribo.lst --ref sptsgd_00/output_cls0.hdf --iters p,p,t --goldstandard --startres 50 --tophat local --parallel thread:4 --threads 4
When that's done, you should have a spt_00 folder containing the results of the 3 iterations we requested. You may take a look at:
- fsc_maskedtight_XX.txt - These are the masked gold-standard resolution curves after each iteration. Double click in the EMAN2 browser to plot them.
- threed_XX.hdf - These are the 3D maps after each iteration. Again, double-click in the browser to visualize.
The 3rd map should look considerably more like a ribosome than the initial model (threed_00.hdf), but the resolution will still be limited. In the next run, we will do more subtilt refinement to push the resolution.
We could have done this all in a single run, but simply including the additional --iters letters except for one key addition. The --maxres 12 argument indicates the highest resolution information to consider in the refinement. If this is not specified, it will be determined automatically based on the results of the previous iteration. This will make the iterations run faster, but it may make them progress towards the final resolution more slowly. So, we use the automatic method for 3 iterations to get the shape correct quickly, then in the second run, push the resolution.
note that --ref points at the final map from the previous run
--loadali2d and --loadali3d load the final alignment parameters from the first run. Note that aliptcls3d files are only produced for 'p' iterations.
--goldcontinue tells the refinement to continue with the even/odd pairs from the previous refinement, rather than phase randomizing the data at high resolution again
--maxres specifies the maximum resolution information to consider during alignment. If omitted, it uses an automatic scheme.
--tophat local enables local resolution measurement and filtration, it adds ~2 minutes per iteration. global will filter everything uniformly. e2help.py tophat
e2spt_refine_new.py --ptcls sets/ribo.lst --ref spt_00/threed_03.hdf --loadali2d spt_00/aliptcls2d_03.lst --loadali3d spt_00/aliptcls3d_02.lst --goldcontinue --iters t,p,t,r,d --keep 0.95 --tophat local --parallel thread:4 --threads 4 --maxres 12
That's it. You hopefully have a ~12 Å resolution map. If you wish to try and push the resolution further, you can follow the Large version of the tutorial
Skip the next 2 sections about the old refinement. Other notes are below that.
Large
The Large data set should have 1000-3000 particles at full sampling, and should readily achieve ~6.5 Å resolution. This is really designed to run on a workstation, not a laptop.
In mid-2022+ versions, this is available from the project manager as New 3D Refinement, you can enter the options from the command below if you prefer to run it that way.
You may need to replace sets/tomobox.lst with whatever you named your set.
- --ref should point at whatever initial model you want to use
Replace both 4s with the number of threads for your machine.
- Replace /home/username/tmp with a folder on a local hard-drive with a decent amount of free space (several GB at a minimum)
e2spt_refine_new.py --ptcls=sets/tomobox.lst --ref=sptsgd_00/output_cls0.hdf --startres=50.0 --goldstandard --sym=c1 --iters=p,p,p,t,t,t --keep=0.95 --tophat=global --parallel=thread:4:/home/username/tmp --threads=4 --m3dthread
If you like you could use the modified iters sequence: p,p,p,t,t,r,d,t but this will take considerably longer to run, and likely produce only very slightly improved results. This alternative includes in-plane rotational subtilt refinement and defocus refinement.
You can (and probably should) look at the results while the job is runing, you should have a spt_00 folder containing the results each completed iteration. You may take a look at:
- fsc_maskedtight_XX.txt - These are the masked gold-standard resolution curves after each iteration. Double click in the EMAN2 browser to plot them.
- threed_XX.hdf - These are the 3D maps after each iteration. Again, double-click in the browser to visualize.
That's it. You hopefully have a ~6.5 Å resolution map when the job finishes, and it should get pretty close to that after 4-6 iterations.
Skip the next 2 sections about the old refinement. Other notes are below that.
Old Subtomogram refinement (~1 hr/iteration)
As an alternative to the new integrated tool above, the older pair of programs is still available. You shouldn't need to do both approaches. This step is similar to the "p" iterations above, though it uses an older algorithm.
This step performs a conventional iterative subtomogram averaging using the full set of particles. Typically it will achieve resolutions in the 15-25 A range with a reasonable number of particles. As it involves 3-D alignment of the full set of particles multiple times, it takes a significant amount of compute time. Higher resolutions are achieved in the next stage after this (subtilt refinement).
For the tutorial tilt-series:
Subtomogram Averaging -> 3D Refinement
set particles to "sets/ribo.lst"
set reference to "output.hdf" from Initial Model Generation
set goldstandard to 30
set mass to 3000
set threads to the number of CPUs on your machine
- Launch
Results will gradually appear in spt_XX/ Feel free to look at intermediate results with the EMAN2 file browser as they appear.
For your own data:
- If your molecule has symmetry, you should specify it, but it's important that the alignment reference you provide has been properly aligned to the symmetry axes of whichever symmetry you specify.
localfilter will use e2fsc.py to compute a local resolution map after each iteration and filter the map accordingly. This is useful for molecules with significant variability.
If you suspect that a large fraction of your particles are "bad" in some way, you may wish to try reducing pkeep, which will hopefully exclude bad particles preferentially over "good" particles.
Old Subtilt refinement (~9 hr/iteration)
This is the second half of the old refinement strategy. It is conceptually similar to the t,p and r iterations in the newer integrated program above.
With the results of a good subtomogram alignment/average, we are now ready to switch to alignment of the individual particle images in each tilt, along with per-particle-per-tilt CTF correction and other refinements. This is effectively a hybrid of single particle analysis and subtomogram averaging, and can readily achieve subnanometer resolution IF the data is of sufficient quality. The tutorial data set is, but many cellular tomograms, for example, are not collected with high resolution in mind, and even with this sort of refinement will be unable to achieve resolutions better than 10-30 A, depending on the data. This process is completely automatic, based on all of the metadata collected up to this point. While it is possible to perform "subtomogram refinement" with subtomograms from any tomogram, Subtilt Refinement cannot operate properly unless all preceding steps occurred within EMAN2.
For the tutorial tilt series:
Subtomogram Averaging -> Sub-tilt Refinement
path should be set to the name of one of a "spt_XX" folder to use as a starting point for the refinement
iter can be -1 to use the last complete iteration in the "spt_XX" folder. Alternatively you can specify a specific iteration to use
parallel should be "thread:N" where N is the number of cores you wish to use on a single machine. This job can be run on a linux cluster if you like: EMAN2/Parallel.
threads should also be set to the number of cores to use on a single machine
- Launch
For your own data:
niters is the number of iterations to run. The default of 4 should achieve convergence in most cases.
keep is the fraction of tilt images to use in the final map. This defaults to 0.5, meaning the worst 1/2 of the tilts for each particle will be discarded. This permits tilts which contain, for example, projections of fiducials or other strong densities, or with large amounts of motion to be automatically excluded in the final reconstruction.
maxalt specifies the maximum tilt angle to include from each particle. Most tilt series are collected such that the small tilt angles will have the least radiation damage, and very often high tilts suffer from more motion artifacts. If you enter, for example, "45" in this box then tilts <-45 and >45 will be discarded automatically. In most cases keep will already serve a similar purpose.
Congratulations! The final result of the tutorial will be found in "subtlt_00/". The final 3-D map will be "threed_04.hdf" with the default parameters. The final gold standard resolution curve will be "fsc_maskedtight_04.txt". The optional steps below are tools you can use to evaluate your results in more detail.
Refinement evaluation (optional)
This tool helps visualize and compare results from multiple subtomogram refinement runs.
Analysis and Visualization -> Evaluate SPT Refinements
In the GUI, you can look at all spt_XX or sptsgd_XX folders and compare the parameters which were used for each, as well as the resulting maps.
- Switch between folder types using the menu at top right.
- Columns can be sorted by clicking on the corresponding header.
- Uncheck items in the list at bottom-right to hide corresponding columns
ShowBrowser will bring up the e2display.py browser in the folder of the selected row.
!PlotFSC will display the "tight" FSC curve over all iterations.
PlotParams will plot the Euler angle distribution and other alignment parameters
- The 8 columns in the plot are:
- 0 - az (EMAN convention Euler angle)
- 1 - alt
- 2 - phi
- 3 - translation in X
- 4 - Y
- 5 - Z
- 6 - alignment score
- 7 - missing wedge coverage
- The 8 columns in the plot are: