Differences between revisions 17 and 27 (spanning 10 versions)
Revision 17 as of 2022-02-16 01:25:53
Size: 32672
Editor: SteveLudtke
Comment:
Revision 27 as of 2022-02-27 05:03:36
Size: 36243
Editor: SteveLudtke
Comment:
Deletions are marked like this. Additions are marked like this.
Line 3: Line 3:
Line 10: Line 9:
 * Documentation of some newly developed tools can be found in [[https://blake.bcm.edu/emanwiki/EMAN2/e2tomo_more | TomoMore]].
 * There is now a newer pipeline for integrated subtomogram and subtilt refinement. Some documentation can be found in [[https://blake.bcm.edu/emanwiki/EMAN2/e2tomo_new | TomoNew]] (frequently updated).
 * Documentation of some newly developed tools can be found in [[https://blake.bcm.edu/emanwiki/EMAN2/e2tomo_more|TomoMore]].
 * There is now a newer pipeline for integrated subtomogram and subtilt refinement. Some documentation can be found in [[https://blake.bcm.edu/emanwiki/EMAN2/e2tomo_new|TomoNew]] (frequently updated).
Line 28: Line 27:
 * run '''[[http://blake.bcm.edu/emanwiki/EMAN2/Programs/e2projectmanager|e2projectmanager.py]]'''   * run '''[[http://blake.bcm.edu/emanwiki/EMAN2/Programs/e2projectmanager|e2projectmanager.py]]''':

{{{
e2projectmanager.py&
}}}
Line 30: Line 33:
 * You may use "Edit Project" from the Project menu to set default values for the project.   * You may use "Edit Project" from the Project menu to set default values for the project.
Line 36: Line 39:
{{attachment:e2pm.png|Project Manager|width=600}} {{attachment:e2pm.png|Project Manager|width="600"}}
Line 50: Line 53:
 * It is critical that the filenames for your data not contain any spaces (replace with underscore) or periods (other than the final period used for the file extension). 
 * "__" (double underscore) is also reserved for describing modified versions of the same file, and should not be used in your image filenames.
 * It is critical that the filenames for your data not contain any spaces (replace with underscore) or periods (other than the final period used for the file extension).
 * "__" (double underscore) is also reserved for describing modified versions of the same file, and should not be used in your image filenames.
Line 58: Line 61:
Line 64: Line 68:
 * ''threads'' = number of physical cores on your machine, optionally *1.25.
 * If you wish to look at the intermediate aligned tilt-series and other files, uncheck ''notmp'', but note that this will significantly increase disk requirements
  * This is not required for the remaining steps in the tutorial, but can be used to help understand how the tomogram alignment works. This requires significant additional disk space. You may consider doing this for only one tomogram.
  * In each ''tomorecon_XX'' folder
 * ''threads'' = number of physical cores on your machine, optionally *1.25.
 * ''notmp'' = checked by default. If you wish to look at the intermediate aligned tilt-series and other files, uncheck this, but note that this will significantly increase disk requirements
  * These files are not required for the remaining steps in the tutorial, but can be used to help understand how the tomogram alignment works. You may consider doing this for only one tomogram.
  * If you uncheck notmp, you will get a ''tomorecon_XX'' folder for each tilt series, containing:
Line 74: Line 78:
{{attachment:tomorecon.png| Tomogram reconstruction |width=600}} {{attachment:tomorecon.png|Tomogram reconstruction|width="600"}}
Line 77: Line 81:
Line 78: Line 83:
 * While the program can automatically compute the orientation of the tilt axis, it can lead to a handedness ambiguity in the tomogram (it happens to be correct in the tutorial data). For your own data, it is recommended to confirm the handedness in a few good tomograms, then provide the correct ''tltax'' value for the reconstruction of all tomograms. To determine the handedness computationally, try the [[https://blake.bcm.edu/emanwiki/EMAN2/e2tomo_more#Determine_the_handedness_of_a_tomogram | tutorial here]] for EMAN2 build after 05/23/2019 (or EMAN>=2.31).  * While the program will automatically locate the tilt axis, there is a 180 degree ambiguity, which can lead to handedness ambiguity in the tomogram (it happens to come out correct in the tutorial data). For your own data, it is recommended to confirm the handedness as described below, then provide the correct ''tltax'' value for the reconstruction of all tomograms.
Line 81: Line 86:
 * The graphical interface only permits 1k or 2k reconstruction sizes. In our experience this is normally sufficient for segmentation or particle picking. 
 * When the sample is thick, some grid-like tiling pattern can be seen in the reconstruction. Checking '''extrapad''' can largely reduce the artifacts. In versions after 2/3/2020, there is also a '''moretile''' option that further eliminates them. Note these artifacts will NOT impact the subtomogram averaging results because the particles are extracted in a separate process. Checking these options can make the reconstruction process more memory consuming, and up to 5 times slower. 
 * The graphical interface only permits 1k or 2k reconstruction sizes. In our experience this is normally sufficient for segmentation or particle picking.
 * When the sample is thick, some grid-like tiling pattern can be seen in the reconstruction. Checking '''extrapad''' can largely reduce the artifacts. In versions after 2/3/2020, there is also a '''moretile''' option that further eliminates them. Note these artifacts will NOT impact the subtomogram averaging results because the particles are extracted in a separate process. Checking these options can make the reconstruction process more memory consuming, and up to 5 times slower.
Line 85: Line 90:
 * There is a new ''patchtrack'' option which may help with refinements that otherwise don't seem to be aligning well. Note that this is not conventional 2-D patchtracking, but a novel 3-D patchtracking routine. This acts as a preprocessing step if specified.
Line 90: Line 96:
Line 105: Line 112:
Line 111: Line 117:

For the tutorial tilt-series:
For the tutorial tilt-series:
Line 119: Line 125:
Line 127: Line 134:

{{attachment:tomo_evaluation.png| Tomogram evaluation |width=600}}
{{attachment:tomo_evaluation.png|Tomogram evaluation|width="600"}}
Line 132: Line 138:
 * On the left is a list of tomograms in the project.   * On the left is a list of tomograms in the project.
Line 142: Line 148:
   * Please note that most tomograms include some out-of-plane tilt (the actual rotation isn't a simple tilt along a single axis), which is taken into account during alignment. This may make it visually appear that the tilt series alignment is not as robust as it actually is.     * Please note that most tomograms include some out-of-plane tilt (the actual rotation isn't a simple tilt along a single axis), which is taken into account during alignment. This may make it visually appear that the tilt series alignment is not as robust as it actually is.
Line 146: Line 152:
  * ''Tiltparams'' is a bit more complicated. It plots a point list with 6 columns and a number of rows corresponding to the images in the selected tilt series. These are the alignment parameters for the tilt series.    * ''Tiltparams'' is a bit more complicated. It plots a point list with 6 columns and a number of rows corresponding to the images in the selected tilt series. These are the alignment parameters for the tilt series.
Line 158: Line 164:

{{attachment:annotation.png| 2D particle picking |width=600}}
{{attachment:annotation.png|2D particle picking|width="600"}}
Line 163: Line 168:
This section is brief and is only an update to the more detailed tutorial: [[http://eman2.org/Programs/tomoseg| TomoSeg]]. Some directory structure and user interfaces have changed in the latest version to match new tomogram workflow as described here: There is a newer tool which can be used for deep-learning based particle picking, which is really a different task than annotation. If you have a GPU and prefer this over the reference based approach outlined in the next section, see: [[EMAN2/e2tomo_more#Automated_particle_selection|New automatic particle picking]]. The annotation tool is still functional and available, but is targeted more at annotation of cellular features: [[http://eman2.org/Programs/tomoseg|TomoSeg]]

This is a brief summary of the annotation-based approach:
Line 166: Line 173:
  * This step is not always necessary for tomograms reconstructed in EMAN2, but may slightly improve results.    * This step is not always necessary for tomograms reconstructed in EMAN2, but may slightly improve results.
Line 168: Line 175:
  * This is a newer interface than previously used for this step. Select a few "Good" (regions containing the feature of interest) and "Bad" (regions not containing the feature of interest) boxes.    * This is a newer interface than previously used for this step. Select a few "Good" (regions containing the feature of interest) and "Bad" (regions not containing the feature of interest) boxes.
Line 178: Line 185:
  * Input both the tomogram and its corresponding segmentation, and the particles coordinates will be written into the metadata file. 
  * Slightly tweaking the threshold parameters may yield better results. 
  * Input both the tomogram and its corresponding segmentation, and the particles coordinates will be written into the metadata file.
  * Slightly tweaking the threshold parameters may yield better results.
Line 183: Line 190:

{{attachment:ptclpicking.png| 3D particle picking |width=600}}
{{attachment:ptclpicking.png|3D particle picking|width="600"}}
Line 192: Line 199:
 * The box size can be set in the main window at the left bottom corner, for this tutorial, use 32 for ribosomes (the unbinned box size is 128).   * The box size can be set in the main window at the left bottom corner, for this tutorial, use 32 for ribosomes (the unbinned box size is 128).
Line 195: Line 202:
 * Hold down Shift when clicking to delete existing boxes. 
 * Boxes are shown as circles, which vary in size depending on the Z distance from the center of the particle. 
 * If you accidentally include one or more particles with nearby gold fiducials or other high contrast artifacts, it may cause some issues with your generated model (do not do that). 
 * Hold down Shift when clicking to delete existing boxes.
 * Boxes are shown as circles, which vary in size depending on the Z distance from the center of the particle.
 * If you accidentally include one or more particles with nearby gold fiducials or other high contrast artifacts, it may cause some issues with your generated model (do not do that).
Line 200: Line 207:
 * The interface supports different box types within a single tomogram. Each type has a label. Make sure the label is consistent if selecting the same feature in different tomograms. 

 * If you skipped the tomogram annotation step, we will pick a few particles here to generate an initial model, and use the initial model as a reference for template matching. 
 * Select 30-50 particles from one tomogram, then close the boxer window. 
 * Do '''not''' use the ''Save'' button in the Options window or any of the menu items related to saving data. Those are available for special purposes. When you change the boxes, your changes are saved immediately and automatically. When you are done, simply close the main window. 
 * The interface supports different box types within a single tomogram. Each type has a label. Make sure the label is consistent if selecting the same feature in different tomograms.

 * If you skipped the tomogram annotation step, we will pick a few particles here to generate an initial model, and use the initial model as a reference for template matching.
 * Select 30-50 particles from one tomogram, then close the boxer window.
 * Do '''not''' use the ''Save'' button in the Options window or any of the menu items related to saving data. Those are available for special purposes. When you change the boxes, your changes are saved immediately and automatically. When you are done, simply close the main window.
Line 209: Line 216:

In this pipeline, the full 1k or 2k tomograms are used only as a reference to identify the location of the objects to be averaged. Now that we have particle locations, the software returns to the original tilt-series, extracts a per-particle tilt-series, and reconstructs each particle in 3-D independently. 

For the tutorial tilt-series:
In this pipeline, the full 1k or 2k tomograms are used only as a reference to identify the location of the objects to be averaged. Now that we have particle locations, the software returns to the original tilt-series, extracts a per-particle tilt-series, and reconstructs each particle in 3-D independently.

For the tutorial tilt-series:
Line 215: Line 222:
  * set ''boxsz_unbin'' to 128.
   * If you had the correct size in the previous step this may not be necessary, but it doesn't hurt.
  * set ''boxsz_unbin'' to 128.
   * If you had the correct size in the previous step this should be the same as leaving the default -1
   * It is fine to use a different (usually larger) box size here if you find it easier to select particles with a smaller box size. For the tutorial, stick with 128, though.
Line 218: Line 226:
  * Launch

 * '''Subtomogram Averaging -> Build Sets''' 
  * ''threads'' = value for your machine
* Launch

 * '''Subtomogram Averaging -> Build Sets'''
Line 224: Line 233:
  
Line 226: Line 235:
Line 230: Line 240:
 
Line 232: Line 242:
{{attachment:initial_model.png| Initial model generation | width=600}}

While intuitively it seems like (since the particles are already in 3-D) the concept of an "initial model" should not be necessary. Unfortunately, due to the missing wedge, and the low resolution of one individual particle (particularly from cells), it is actually critical to make a good starting average. Historically it has been challenging to get a good starting model, depending on the shape of the molecule. This new procedure based on stochastic gradient descent has proven to be quite robust, but it is difficult for the computer to tell when it has converged sufficiently. For this reason, the default behavior is to run much longer than is normally required, and have a human decide when it's "good enough" and terminate the process. If you use a small ''shrink'' value and let it run to completion, it can take some time to run. This is harmless, but unnecessary.

For the tutorial tilt-series:
While intuitively it seems like (since the particles are already in 3-D) the concept of an "initial model" should not be necessary. Unfortunately, due to the missing wedge, and the low resolution of one individual particle (particularly from cells), it is actually critical to make a good starting average. Historically it has been challenging to get a good starting model, depending on the shape of the molecule. This new procedure based on stochastic gradient descent has proven to be quite robust, but it is difficult for the computer to tell when it has converged sufficiently. For this reason, the default behavior is to run much longer than is normally required, and have a human decide when it's "good enough" and terminate the process. If you use a small ''shrink'' value and let it run to completion, it can take some time to run. This is harmless, but unnecessary. While the section below the solid line remains fully functional, a new program available since 2021 does a much more efficient job of making initial models. It hasn't been integrated into e2projectmanager yet, but it is enough of an improvement, we will go ahead and use it here regardless. The original instructions are preserved below the horizontal line if you prefer the older approach.

If you didn't launch e2projectmanager with an & at the end of the line, you will need to exit it (close the windows) to run the following command. Replace the 4 in thread:4 with the appropriate number of threads for your computer. If you called your set something other than initribo, you may need to change that as well.

{{{
e2spt_sgd_new.py sets/initribo.lst --res 50 --parallel thread:4
}}}
The second program will produce output like:

{{{
Gathering metadata...
 69/69
iter 0, class 0:
17 jobs on 4 CPUs
iter 1, class 0:
17 jobs on 4 CPUs
iter 2, class 0:
17 jobs on 4 CPUs
}}}
Once it gets past 3-4 iterations, you can use the browser to look in ''sptsgd_00'', and double-click on ''output_cls0.hdf''. This file will change as more iterations complete. It contains the results of the most recent iteration. If you double click on it again later, it will load another map into the same 3-D display. You can then open the control-panel for the 3-D display (middle-click) and use the ''Seq'' slider to cycle through the maps. When you are satisfied with the quality of the initial model, press ctrl-C, which will kill the initial model generating job.

At this point you can also close the browser window and relaunch ''e2projectmanager.py''.

----
{{attachment:initial_model.png|Initial model generation|width="600"}}

This section is the older program, which is still functional, and is integrated into the project manager. If you completed the section above the line, you can skip to the Template Matching section.

For the tutorial tilt-series:
Line 238: Line 273:
  * ''particles'' should be set to the sets/ribo.lst file you just created (whatever name you used).   * ''particles'' should be set to the sets/initribo.lst file you just created (or whatever name you used).
Line 242: Line 277:
  * The default ''niter'' of 5 is typically much more than is required    * The default ''niter'' of 5 is typically much more than is required
Line 247: Line 282:
Line 254: Line 290:
Line 258: Line 293:
  * browse to select ''tomograms''. Select all 3 tomograms.
  * set ''reference'' to the output.hdf file you produced in the previous step.
  * set ''label'' to "ribo"
  * set ''nptcl'' to 150 (the maximum number of particles per tomogram)
  * ''tomograms'' -> browse and select all 3 tomograms.
  * ''reference'' = the initial model you produced in the previous step
  * ''label'' = ribo
  * ''nptcl'' = 150
Line 263: Line 298:
  * ''vthr'' = 5
   * if using an older version of EMAN2, you may wish to use the default of 10, but with the current version, 10 may not find any particles and crash.
  * ''threads'' = the usual number
Line 269: Line 307:
Line 275: Line 312:
Line 277: Line 315:
  * set ''boxsz_unbin'' to 128.    * set ''boxsz_unbin'' to 128.
Line 281: Line 319:
 * '''Subtomogram Averaging -> Build Sets'''   * '''Subtomogram Averaging -> Build Sets'''
Line 286: Line 324:
== New integrated refinement program ==
There is a new refinement program which implements both traditional subtomogram averaging and subtilt refinement in a single program. Like the other new software referenced above, this new program is not yet integrated into e2projectmanager, and must be run from the command line. This is an alternative to the next two major sections (Subtomogram Refinement and Subtilt Refinement). The full tutorial on the new program is [[https://blake.bcm.edu/emanwiki/EMAN2/e2tomo_new|here]].

You may need to replace ''sets/ribo.lst'' with whatever you named your set. Replace both ''4''s with the number of threads for your machine. If you didn't use the "new" style initial model generation above, you may also need to alter --ref. Run the following with necessary changes:

{{{
e2spt_refine_new.py --ptcls sets/ribo.lst --ref sptsgd_01/output_cls0.hdf --iters p,p,p,t,p,t,r --parallel thread:4 --threads 4
}}}
Line 287: Line 333:
{{attachment:refinement.png| 3D refinement | width=600}} {{attachment:refinement.png|3D refinement|width="600"}}
Line 292: Line 338:
Line 300: Line 347:
Results will gradually appear in spt_XX/
Feel free to look at intermediate results with the EMAN2 file browser as they appear.
Results will gradually appear in spt_XX/ Feel free to look at intermediate results with the EMAN2 file browser as they appear.
Line 304: Line 350:
Line 309: Line 356:

{{attachment:subtlt_dir.png| Subtilt refinement directory |width=600}}
{{attachment:subtlt_dir.png|Subtilt refinement directory|width="600"}}
Line 315: Line 361:
Line 323: Line 370:
Line 326: Line 374:
 
Line 330: Line 378:

{{attachment:refinement_evaluation.png| Refinement evaluation |width=600}}
This tool helps visualize and compare results from multiple subtomogram refinement runs. 
{{attachment:refinement_evaluation.png|Refinement evaluation|width="600"}} This tool helps visualize and compare results from multiple subtomogram refinement runs.
Line 335: Line 381:
  * In the GUI, you can look at all ''spt_XX'' or ''sptsgd_XX'' folders and compare the parameters which were used for each, as well as the resulting maps. 
  * Switch between folder types using the menu at top right. 
  * Columns can be sorted by clicking on the corresponding header. 
  * In the GUI, you can look at all ''spt_XX'' or ''sptsgd_XX'' folders and compare the parameters which were used for each, as well as the resulting maps.
  * Switch between folder types using the menu at top right.
  * Columns can be sorted by clicking on the corresponding header.
Line 339: Line 385:
  * ''!ShowBrowser'' will bring up the ''[[http://blake.bcm.edu/emanwiki/EMAN2/Programs/e2display|e2display.py]]'' browser in the folder of the selected row.    * ''!ShowBrowser'' will bring up the ''[[http://blake.bcm.edu/emanwiki/EMAN2/Programs/e2display|e2display.py]]'' browser in the folder of the selected row.

EMAN2 Tomography mini-Workflow Tutorial

This version of the EMAN2 Tomography Pipeline tutorial is designed to run on well equipped laptops or standard workstations, unlike the full tutorial which requires a well-equipped tomography workstation. It should be possible to complete this tutorial in a reasonable time on a computer with 16 GB of ram and 4 cores, but resolution will be limited to ~15 A, not the subnanometer resolution provided by the main tutorial.

  • This tutorial is best suited for EMAN2 built after 09/27/2018. Not everything described in the tutorial was functioning yet in the 2.22 release.
  • This version of the tutorial is based on a subset of reduced sampling data from the same EMPIAR data set as the main tutorial. This should be downloaded from the EMAN2 website. The pixel size for this data is 3.93 A/pix.
  • To cite:
    • Chen, M., Bell, J.M., Shi, X. et al. A complete data processing workflow for cryo-ET and subtomogram averaging. Nat Methods 16, 1161–1168 (2019)
  • Documentation of some newly developed tools can be found in TomoMore.

  • There is now a newer pipeline for integrated subtomogram and subtilt refinement. Some documentation can be found in TomoNew (frequently updated).

Computer Requirements

  • This reduced version of the tutorial can be completed on a well equipped laptop or standard desktop workstation.
  • Minimum recommended configuration (timing estimates based on single quad-core computer):
    • 16 GB RAM
    • 4 cores @ >2 ghz

    • 40 gb free disk space
    • a high performance disk (SSD or RAID) will significantly reduce runtimes

Note: Anyplace in EMAN2 where you are requested to enter the number of threads to use, you should specify the number of cores your machine has. Computers are often advertised as 4 core/8 thread or 8 core/16 thread. Trying to run image processing using this advertised number of threads will usually make processing run slower, not faster. You may optionally increase the number of cores by ~25%, ie - on a 4 core machine, 5 may be a reasonable number to specify.

Download Data

Prepare input files (~2 minutes)

e2projectmanager.py&
  • Make sure any EMAN2 commands you run are executed from within this folder (not any subfolder)
  • You may use "Edit Project" from the Project menu to set default values for the project.
    • If you downloaded our prepared data set, it will already contain an info folder containing the project settings, so you should not need to change anything.

    • For this project use 3000 kDa, 2.7 mm Cs, 300 keV and 3.93 A/pix.
    • The mass need not be precise, it is only used to keep isosurface values roughly self-consistent.
  • Make sure the workflow mode is set to "TOMO" not "SPR"

Project Manager

  • Raw Data -> Import tilt series

    • Files -> select the 3 provided .hdf files

    • rawtlt, mdoc -> leave these blank

    • invert should not be selected

    • apix = 3.93, in later steps you can use -1, which tells it to use the known value

    • import_tiltseries = selected

    • importation = copy

    • compressbits = 5 (8 is fine as well, but will make file sizes slightly larger)

    • Once the options are set, press Launch

When working with your own data:

  • It is critical that the filenames for your data not contain any spaces (replace with underscore) or periods (other than the final period used for the file extension).
  • "" (double underscore) is also reserved for describing modified versions of the same file, and should not be used in your image filenames.

  • If your tilt series isn't a single stack file, but is many individual images instead, you will need to use Generate tiltseries to build an image stack

Tiltseries Alignment and Tomogram Reconstruction (10 min)

Alignment of the tilt-series is performed iteratively in conjunction with tomogram reconstruction. Tomograms are not normally reconstructed at full resolution, generally limited to 1k x 1k or 2k x 2k, but the tilt-series are aligned at full resolution. For high resolution subtomogram averaging, the raw tilt-series data is used, based on coordinates from particle picking in the downsampled tomograms. On a typical workstation reconstruction takes about 4-5 minutes per tomogram.

For the tutorial tilt-series:

  • 3D Reconstruction -> Reconstruct Tomograms

  • alltiltseries = selected

    • alternatively you can select one or more tilt series from the tiltseries folder

  • correctrot = selected

  • tltstep = 2

  • clipz = 64

  • threads = number of physical cores on your machine, optionally *1.25.

  • notmp = checked by default. If you wish to look at the intermediate aligned tilt-series and other files, uncheck this, but note that this will significantly increase disk requirements

    • These files are not required for the remaining steps in the tutorial, but can be used to help understand how the tomogram alignment works. You may consider doing this for only one tomogram.
    • If you uncheck notmp, you will get a tomorecon_XX folder for each tilt series, containing:

      • landmark_0X.txt has the location of the landmarks (which may be fiducials if present) in each iteration

      • samples_0X.hdf shows the top and side view of those landmarks

      • ptclali_0X.hdf has the trace of each landmark throughout the tilt series (they should stay at the center of image all the time if the alignment is good)

      • tomo_0X.hdf is the reconstruction after each iteration

  • Launch

Tomogram reconstruction

When working with your own data:

  • Either specify the correct tltstep if the tilt series is in order from one extreme to the other, or specify the name of a rawtlt file (as produced by serialem/IMOD).

  • While the program will automatically locate the tilt axis, there is a 180 degree ambiguity, which can lead to handedness ambiguity in the tomogram (it happens to come out correct in the tutorial data). For your own data, it is recommended to confirm the handedness as described below, then provide the correct tltax value for the reconstruction of all tomograms.

  • In most cases, the default npk should be fine. If fiducials are present, it is not necessary to adjust this number to match the number of fiducials. The program will use any high contrast areas it finds as potential landmarks.

  • bytile should normally be selected, as it will normally produce better quality reconstructions at higher speed. If 2k or larger tomograms are created, memory consumption may be high, and you should check the program output for the anticipated RAM usage.

  • The graphical interface only permits 1k or 2k reconstruction sizes. In our experience this is normally sufficient for segmentation or particle picking.
  • When the sample is thick, some grid-like tiling pattern can be seen in the reconstruction. Checking extrapad can largely reduce the artifacts. In versions after 2/3/2020, there is also a moretile option that further eliminates them. Note these artifacts will NOT impact the subtomogram averaging results because the particles are extracted in a separate process. Checking these options can make the reconstruction process more memory consuming, and up to 5 times slower.

  • When the sample is thin (purified protein, not cells), it is useful to check correctrot to automatically position tomograms flat in ice

  • It can also be helpful with thin ice to specify a clipz value to generate thinner tomograms (perhaps 64 or 96 for a 1k tomogram).

  • There is a new patchtrack option which may help with refinements that otherwise don't seem to be aligning well. Note that this is not conventional 2-D patchtracking, but a novel 3-D patchtracking routine. This acts as a preprocessing step if specified.

Handedness Check (can be skipped in the tutorial)

EMAN2 includes a novel procedure for determining the correct tilt axis for a tilt series based on defocus estimates across the tilted images in a tilt series. The tutorial data set comes out correctly without running this check, but when working with your own data, this step is highly recommended. Once you know the correct tilt axis direction to use for a given microscope/camera, you shouldn't need to run this test on every data set, but it may not be a bad idea even then, as there are various possible configuration/software errors on the instrument which could potentially cause inconsistent results.

For the tutorial tilt-series:

  • Subtomogram Averaging -> CTF Estimation

  • tiltseries = select any one tilt series

  • alltiltseries = not selected

  • voltage and cs (double check that values are correct)

  • checkhand = selected

  • Launch

You will need to look at the console where you launched e2projectmanager to see the results of the test. It should look something like:

Average score: Current hand - 4.133, flipped hand - 3.290
Defocus std: Current hand - 0.110, flipped hand - 0.165
Current hand is better than the flipped hand in 86.4% tilt images
The handedness (--tltax=-4.1) seems to be correct. Rerun CTF estimation without the checkhand option to finish the process.

If you run this check on multiple images and it seems that they indicate a tilt axis/handedness error, then you need to return to the previous step (Tomogram Reconstruction) and run this again for all of your tomograms, with the correct tilt axis entered in the corresponding box. The same tilt axis should be used for all tilt series collected under the same conditions on the same instrument.

Note: This method removes almost all of the ambiguity about particle handedness. The one potential issue is that the MRC file format uses a non-conventional origin for images. If the data collection software doesn't take this into account, the images may be flipped when written to disk. The easiest way to check the software would be to collect 2 images of the same target and save them directly into different file formats, then checking (in different software) whether the two images appear to have the same handedness

CTF Estimation (<10 min)

For the tutorial tilt-series:

  • Subtomogram Averaging -> CTF Estimation

  • alltiltseries = selected, note that doing this will override anything present in the tiltseries field

  • checkhand = not selected

  • Launch

When working with your own data:

  • The first two options, dfrange and psrange indicate the defocus and phase shift range to search. They take the format of “start, end, step”, so “2, 5, .1” will search defocus from 2 to 5 um with a step size of 0.1. Units for phase shift is degrees.

  • For images taken with volta phase plate, we usually have dfrange of “0.2,2,0.1” and psrange of “60,120,2”.

Note: this program is only estimating CTF parameters, taking tilt into account. It is not performing any phase-flipping corrections on whole tomograms. CTF correction is performed later as a per-particle process. This process requires metadata determined during tilt-series alignment, so it cannot be used with tomograms reconstructed using other software packages.

Note: In >2022 snapshots of EMAN2 it is possible after CTF correction to return to the 3-D reconstruction step and produce CTF corrected whole tomograms, but this does nothing useful when following the EMAN2 pipeline. If you wish to compare EMAN2 tomograms with other software doing CTF correction, this could potentially be useful

Tomogram reconstruction evaluation (optional)

Tomogram evaluation

Analysis and visualization -> Evaluate tomograms can be used to evaluate the quality of your tilt series alignments and tomogram reconstructions. This tool will show more information as you progress through the tutorial, but can be used already at this point to make various assessments of your tomograms. Note that some of this information may not be available if you had notmp checked during the reconstruction.

  • On the left is a list of tomograms in the project.
    • Clicking the header of any column will sort the table by that attribute.
    • #box is the number of boxes in the tomogram

    • loss is the average landmark uncertainty in nm. You should not try to compare this number to, for example, the fiducial alignment error in IMOD, as it is computed in a completely different way. This number can be useful to identify specific tilt series within a project which aren't aligning as well as others, but the absolute number is not a useful value to report/analyze. Even if this number were >5 nm, it is still quite possible to achieve a subnanometer resolution subtomogram average.

    • defocus is the average defocus of the tilt series.

  • On the right
    • The image at the top is the central slice through the tomogram
    • the show2d button displays the selected tomogram in a slice-wise view.

    • ShowTilts shows the corresponding raw tilt series

      • Please note that most tomograms include some out-of-plane tilt (the actual rotation isn't a simple tilt along a single axis), which is taken into account during alignment. This may make it visually appear that the tilt series alignment is not as robust as it actually is.
    • Boxer opens the 3D particle picker

    • PlotLoss will plot the fiducial error for each tilt

    • PlotCtf plot the defocus and phase shift at the center of each tilt image

    • Tiltparams is a bit more complicated. It plots a point list with 6 columns and a number of rows corresponding to the images in the selected tilt series. These are the alignment parameters for the tilt series.

      • You can adjust X Col and Y Col in the plot control panel (middle click the plot). The columns represent:

        • 0 - tilt ID
        • 1 - translation along x
        • 2 - translation along y
        • 3 - tilt angle around y
        • 4 - tilt angle around x
        • 5 - tilt angle around z
    • The first panel below the buttons are the types of particles and how many of that type are in the project
    • The last box is reserved for comments for each tomogram. You can fill in any comments you have on a specific tomogram and it will be saved for future reference.

Tomogram annotation (optional alternative to process below, GPU recommended)

2D particle picking

  • Since the tutorial data set is purified ribosomes, this step can be skipped for the tutorial data, and you can move on to template-based particle picking. For cells or other types of complex specimens, tomogram annotation can be used to produce locations of different types of objects.

There is a newer tool which can be used for deep-learning based particle picking, which is really a different task than annotation. If you have a GPU and prefer this over the reference based approach outlined in the next section, see: New automatic particle picking. The annotation tool is still functional and available, but is targeted more at annotation of cellular features: TomoSeg

This is a brief summary of the annotation-based approach:

  • Segmentation -> Preprocess tomogram

    • This step is not always necessary for tomograms reconstructed in EMAN2, but may slightly improve results.
  • Segmentation -> Box Training References

    • This is a newer interface than previously used for this step. Select a few "Good" (regions containing the feature of interest) and "Bad" (regions not containing the feature of interest) boxes.
    • "~" and "1" on the keyboard can be used to move along the Z axis.
    • The new interface permits different types of features to be identified in a single session and in the same tomogram.
    • If the different features of interest have very different scale, it is always better to keep the box size at 64, and instead rescale the tomogram. As long as the rescaling is done using EMAN2 utilities, the program will correctly keep track of the geometry relative to the original tomogram & tilt series.

    • if you are doing this with the tutorial data, you would only have 2 classes of particles "ribo_good" and "ribo_bad".
    • When pressing Save all visible particles (box checked next to the class name) will be saved

  • The rest of the annotation process remain unchanged from the original tutorial, except that now, all trained neural networks and training results are saved in the neuralnets folder, and all segmented maps are in the segmentations folder. You now only specify the label of the output file instead of the full file name.

  • Segmentation -> Find particles from segmentation to turn segmented maps into particle coordinates.

    • Input both the tomogram and its corresponding segmentation, and the particles coordinates will be written into the metadata file.
    • Slightly tweaking the threshold parameters may yield better results.
    • featurename will become the label of particles generated. Those particles can be viewed in the particle picking step and processed in the following protocols.

Particle picking (10-15 min)

3D particle picking

  • Time above is to manually select 30-50 reference particles.
  • You can launch the particle picker in two equivalent ways:
    • Subtomogram averaging -> Manual boxing, select tomogram, Launch

    • Analysis and visualization -> Evaluate tomograms as above, press the "Boxer" button

  • two windows will appear Main Window and Options. If you don't see Options it is probably hiding behind the main window.

  • in the Options window, rename the set of boxes to "initribo". This will be used as the label in later stages

  • The box size can be set in the main window at the left bottom corner, for this tutorial, use 32 for ribosomes (the unbinned box size is 128).
    • This is NOT the same as the size listed near the word erase in another window, which is the size of the eraser.

  • left click and drag to place and reposition boxes in any of the 3 views
  • Hold down Shift when clicking to delete existing boxes.
  • Boxes are shown as circles, which vary in size depending on the Z distance from the center of the particle.
  • If you accidentally include one or more particles with nearby gold fiducials or other high contrast artifacts, it may cause some issues with your generated model (do not do that).
  • Go through slices along z-axis using ‘~’ and ‘1’ on the keyboard, or using the slider in the lower right of the window

  • It may be easier to locate particles if you adjust the Filt slider to ~70, but it will slow things down

  • The interface supports different box types within a single tomogram. Each type has a label. Make sure the label is consistent if selecting the same feature in different tomograms.
  • If you skipped the tomogram annotation step, we will pick a few particles here to generate an initial model, and use the initial model as a reference for template matching.
  • Select 30-50 particles from one tomogram, then close the boxer window.
  • Do not use the Save button in the Options window or any of the menu items related to saving data. Those are available for special purposes. When you change the boxes, your changes are saved immediately and automatically. When you are done, simply close the main window.

  • If you did the previous optional annotation step above, you will be able to see the selected particles here, and if you like, manually update them.

Particle extraction (2 min)

In this pipeline, the full 1k or 2k tomograms are used only as a reference to identify the location of the objects to be averaged. Now that we have particle locations, the software returns to the original tilt-series, extracts a per-particle tilt-series, and reconstructs each particle in 3-D independently.

For the tutorial tilt-series:

  • Subtomogram Averaging -> Extract Particles

    • check alltomograms

    • set boxsz_unbin to 128.

      • If you had the correct size in the previous step this should be the same as leaving the default -1
      • It is fine to use a different (usually larger) box size here if you find it easier to select particles with a smaller box size. For the tutorial, stick with 128, though.
    • enter the label you used when picking particles ("initribo" if you followed the instructions above)
    • threads = value for your machine

    • Launch
  • Subtomogram Averaging -> Build Sets

    • check allparticles

    • Launch
      • This will generate particle sets, which are virtual particle stacks that consist of particles with the same label from different tomograms.

For your own data

  • If the box size is correct when you select particles from the GUI, you can leave boxsz_unbin as -1, so the program will keep that box size (scaled to the original tilt series)

  • If your particles are deeply buried in other densities, using a bigger padtwod may help, but doing so may significantly increase the memory usage and slow down the process.

  • With CTF information present, it generally does not hurt to check wiener, which filters the 2D particles by SSNR before reconstructing them in 3D.

  • Specify a binning factor in shrink to produce downsampled particles if your memory/storage/CPU time is limited, but it will also limit the resolution you can achieve.

Initial model generation (10 - 60 min)

While intuitively it seems like (since the particles are already in 3-D) the concept of an "initial model" should not be necessary. Unfortunately, due to the missing wedge, and the low resolution of one individual particle (particularly from cells), it is actually critical to make a good starting average. Historically it has been challenging to get a good starting model, depending on the shape of the molecule. This new procedure based on stochastic gradient descent has proven to be quite robust, but it is difficult for the computer to tell when it has converged sufficiently. For this reason, the default behavior is to run much longer than is normally required, and have a human decide when it's "good enough" and terminate the process. If you use a small shrink value and let it run to completion, it can take some time to run. This is harmless, but unnecessary. While the section below the solid line remains fully functional, a new program available since 2021 does a much more efficient job of making initial models. It hasn't been integrated into e2projectmanager yet, but it is enough of an improvement, we will go ahead and use it here regardless. The original instructions are preserved below the horizontal line if you prefer the older approach.

If you didn't launch e2projectmanager with an & at the end of the line, you will need to exit it (close the windows) to run the following command. Replace the 4 in thread:4 with the appropriate number of threads for your computer. If you called your set something other than initribo, you may need to change that as well.

e2spt_sgd_new.py sets/initribo.lst --res 50 --parallel thread:4

The second program will produce output like:

Gathering metadata...
 69/69
iter 0, class 0:
17 jobs on 4 CPUs
iter 1, class 0:
17 jobs on 4 CPUs
iter 2, class 0:
17 jobs on 4 CPUs

Once it gets past 3-4 iterations, you can use the browser to look in sptsgd_00, and double-click on output_cls0.hdf. This file will change as more iterations complete. It contains the results of the most recent iteration. If you double click on it again later, it will load another map into the same 3-D display. You can then open the control-panel for the 3-D display (middle-click) and use the Seq slider to cycle through the maps. When you are satisfied with the quality of the initial model, press ctrl-C, which will kill the initial model generating job.

At this point you can also close the browser window and relaunch e2projectmanager.py.


Initial model generation

This section is the older program, which is still functional, and is integrated into the project manager. If you completed the section above the line, you can skip to the Template Matching section.

For the tutorial tilt-series:

  • Subtomogram Averaging -> Generate Initial Model

    • particles should be set to the sets/initribo.lst file you just created (or whatever name you used).

    • set shrink to 2, 3 or 4

      • 2 will run slowly but will produce a more detailed initial model (not really necessary)
    • increasing batchsize will use more cores (if you have more than 12), and may cause it to converge to the correct answer in fewer iterations, but each iteration will not become faster.

    • The default niter of 5 is typically much more than is required

    • Launch
      • You can terminate the job as soon as sptsgd_00/output.hdf looks reasonable. If you display the progress monitor (4th icon on the right side of the project manager), you can easily kill the job when you're happy. Usually this will take about 10 minutes for the tutorial data.

For your own data:

  • If your particle has known symmetry, specify that EMAN2/Symmetry

  • The symmetry you specify will not be imposed on the map unless you also check applysym, but the map will be rotationally aligned so the symmetry axes are in the correct direction, which will make it easier to apply symmetry in later steps. We do not generally recommend checking this box in this step.

  • setting shrink to something in the range of 2-4 will make the runtime faster but, depending on the shape, could potentially cause problems.

  • using more than the minimal 30-50 particles is fine. If you have a very large set of selected particles, go ahead and use them all. This will not slow the process down at all, since it's stochastic.
  • it is critical that the full sampling box size of the extracted particles divided by shrink be divisible by 2. If not, the program will crash.

Template matching (5 min)

In this step, we will use the initial model you just produced as a template for finding all of the ribosomes in all 4 tomograms. If you completed the Tomogram Annotation step above, and have already extracted a full set of 1000+ particles, then you can skip this step, as we already have all of the particles. Note that here, and everywhere else in the tomography pipeline, reconstructed particles have positive contrast (look white in projection) and tomograms/tilt series have negative contrast (look dark in projection). If you wish to use a reference volume from the PDB or somesuch, then it should have positive contrast as is normal in the single particle CryoEM field.

  • Subtomogram Averaging -> Reference Based Boxing

    • tomograms -> browse and select all 3 tomograms.

    • reference = the initial model you produced in the previous step

    • label = ribo

    • nptcl = 150

      • IMPORTANT NOTE: There are more particles than this in these images. We limit this to 150 from each tomogram so the tutorial runs faster. If you are unconcerned with speed, you can increase this number, but if you're doing that, you may consider running the full tutorial instead.

    • vthr = 5

      • if using an older version of EMAN2, you may wish to use the default of 10, but with the current version, 10 may not find any particles and crash.
    • threads = the usual number

    • Launch
  • when this finishes, you can use the same Manual Boxing tool you used before to look at the particles which were selected. You may wish to manually remove any bad particles it selected. For the tutorial data set or other tomograms of purified protein, this process should work pretty well. For cells you might wish to use the Tomogram Annotation method above.

  • note that this process stores 3-D particle locations in the appropriate info/* files, but does not extract particles from the micrographs

Particle extraction (~15 min)

Again, if you already did Tomogram Annotation above, this step isn't necessary. It is only required if you just did Template Matching.

Since this involves several thousand particles instead of 30-50, it will take quite a lot longer to run. The actual time will depend partially on the speed of your storage.

For the tutorial tilt-series:

  • Subtomogram Averaging -> Extract Particles

    • check alltomograms

    • set boxsz_unbin to 128.

    • set label to "ribo"

    • Launch
  • Subtomogram Averaging -> Build Sets

    • check allparticles

    • Launch
      • This will generate particle sets, which are virtual particle stacks that consist of particles with the same label from different tomograms.

New integrated refinement program

There is a new refinement program which implements both traditional subtomogram averaging and subtilt refinement in a single program. Like the other new software referenced above, this new program is not yet integrated into e2projectmanager, and must be run from the command line. This is an alternative to the next two major sections (Subtomogram Refinement and Subtilt Refinement). The full tutorial on the new program is here.

You may need to replace sets/ribo.lst with whatever you named your set. Replace both 4s with the number of threads for your machine. If you didn't use the "new" style initial model generation above, you may also need to alter --ref. Run the following with necessary changes:

e2spt_refine_new.py --ptcls sets/ribo.lst --ref sptsgd_01/output_cls0.hdf --iters p,p,p,t,p,t,r --parallel thread:4 --threads 4

Subtomogram refinement (~1 hr/iteration)

3D refinement

This step performs a conventional iterative subtomogram averaging using the full set of particles. Typically it will achieve resolutions in the 15-25 A range with a reasonable number of particles. As it involves 3-D alignment of the full set of particles multiple times, it takes a significant amount of compute time. Higher resolutions are achieved in the next stage after this (subtilt refinement).

For the tutorial tilt-series:

  • Subtomogram Averaging -> 3D Refinement

    • set particles to "sets/ribo.lst"

    • set reference to "output.hdf" from Initial Model Generation

    • set goldstandard to 30

    • set mass to 3000

    • set threads to the number of CPUs on your machine

    • Launch

Results will gradually appear in spt_XX/ Feel free to look at intermediate results with the EMAN2 file browser as they appear.

For your own data:

  • If your molecule has symmetry, you should specify it, but it's important that the alignment reference you provide has been properly aligned to the symmetry axes of whichever symmetry you specify.
  • localfilter will use e2fsc.py to compute a local resolution map after each iteration and filter the map accordingly. This is useful for molecules with significant variability.

  • If you suspect that a large fraction of your particles are "bad" in some way, you may wish to try reducing pkeep, which will hopefully exclude bad particles preferentially over "good" particles.

Subtilt refinement (~9 hr/iteration)

Subtilt refinement directory

With the results of a good subtomogram alignment/average, we are now ready to switch to alignment of the individual particle images in each tilt, along with per-particle-per-tilt CTF correction and other refinements. This is effectively a hybrid of single particle analysis and subtomogram averaging, and can readily achieve subnanometer resolution IF the data is of sufficient quality. The tutorial data set is, but many cellular tomograms, for example, are not collected with high resolution in mind, and even with this sort of refinement will be unable to achieve resolutions better than 10-30 A, depending on the data. This process is completely automatic, based on all of the metadata collected up to this point. While it is possible to perform "subtomogram refinement" with subtomograms from any tomogram, Subtilt Refinement cannot operate properly unless all preceding steps occurred within EMAN2.

For the tutorial tilt series:

  • Subtomogram Averaging -> Sub-tilt Refinement

    • path should be set to the name of one of a "spt_XX" folder to use as a starting point for the refinement

    • iter can be -1 to use the last complete iteration in the "spt_XX" folder. Alternatively you can specify a specific iteration to use

    • parallel should be "thread:N" where N is the number of cores you wish to use on a single machine. This job can be run on a linux cluster if you like: EMAN2/Parallel.

    • threads should also be set to the number of cores to use on a single machine

    • Launch

For your own data:

  • niters is the number of iterations to run. The default of 4 should achieve convergence in most cases.

  • keep is the fraction of tilt images to use in the final map. This defaults to 0.5, meaning the worst 1/2 of the tilts for each particle will be discarded. This permits tilts which contain, for example, projections of fiducials or other strong densities, or with large amounts of motion to be automatically excluded in the final reconstruction.

  • maxalt specifies the maximum tilt angle to include from each particle. Most tilt series are collected such that the small tilt angles will have the least radiation damage, and very often high tilts suffer from more motion artifacts. If you enter, for example, "45" in this box then tilts <-45 and >45 will be discarded automatically. In most cases keep will already serve a similar purpose.

Congratulations! The final result of the tutorial will be found in "subtlt_00/". The final 3-D map will be "threed_04.hdf" with the default parameters. The final gold standard resolution curve will be "fsc_maskedtight_04.txt". The optional steps below are tools you can use to evaluate your results in more detail.

Refinement evaluation (optional)

Refinement evaluation This tool helps visualize and compare results from multiple subtomogram refinement runs.

  • Analysis and Visualization -> Evaluate SPT Refinements

    • In the GUI, you can look at all spt_XX or sptsgd_XX folders and compare the parameters which were used for each, as well as the resulting maps.

    • Switch between folder types using the menu at top right.
    • Columns can be sorted by clicking on the corresponding header.
    • Uncheck items in the list at bottom-right to hide corresponding columns
    • ShowBrowser will bring up the e2display.py browser in the folder of the selected row.

    • !PlotFSC will display the "tight" FSC curve over all iterations.

    • PlotParams will plot the Euler angle distribution and other alignment parameters

      • The 8 columns in the plot are:
        • 0 - az (EMAN convention Euler angle)
        • 1 - alt
        • 2 - phi
        • 3 - translation in X
        • 4 - Y
        • 5 - Z
        • 6 - alignment score
        • 7 - missing wedge coverage

EMAN2/e2TomoSmall (last edited 2024-07-14 21:59:58 by MuyuanChen)